06-27-1979 HUCM's. Special Meeting June 27, 1979 Commissioners Quade and Filk were present, Commissioner Tracy was absent, also present were Ivan Larson and Ruth Hakel. The meeting was called to order by President Quade at 1:25 p.m. As a result of a recommendation for a rate change made by the Utilities' Auditors and Consulting Engineers, a motion was made by Commissioner Filk and seconded by Commissioner Quade to adopt the following rate changes. The motion was carried. r 10 • HU'TCHINSON UTILITIES CO'- alISSION ER -7 -79 ELECTRIC RESIDENTIAL SERVICt, AVAILABILITY: Available for domestic purposes only, in a single or multiple residence. One meter single phase. First 300 KWH per month - - -- 6.00c per KWIT Excess KWH per month - - -- 4.00C per KWH Minimum monthly charge: $1.50 MULTIPLE DWELLING, APARTMENT HOUSES, ETC. All newly connected multiple dwelltnp units shall have one meter per unit, also a house meter. Multiple dwelling units now connected through one meter may be serviced. The minimum bill and all energy h1ncks shall be multiplied by the number of units served. This rate is subject to Power Cost Adjustment, U/0 I HUTCHINSON UTILITIES CWZU SSION ER- 1 -7 -79 ALL ELECTRIC RESIDENTIAL SERVICE AVAILABILITY: Available to any residential customer in a single or multiple residence for domestic purposes only through one meter on approved space heating installation. For newly connected consumers to qualify for this rate, the residence must have 100% electric space heating. One meter single phase. First 300 KWH per month - -- 6.000 per KWH Next 500 KWII per month - - -- 4.000 per KWfi Excess KW11 per month - - -- 3.25C per KWH Minimum monthly charge: $1.50 These rates are subject to Power Cost Adjustment. a D .2.a HUTCHINSON UTILITIES COM11';`,[0,,1 ESG -7 -79 ELECTRIC SMALL GENERAL tiF.I:VTCE APPLICABILITY: Applicable to any customer for single or three phase electric service with less than 50 K14 demand supplied through one meter at the secondary vo l tage at that location. October - May First 150 KW11 per month 8.22C per KWiI Next 350 K1411 per month 6.31.0 per KMf Next 1500 KWII per month 4.72c per KW11 Next 2000 KWIC per month 4.19C per K141I Excess KWH per month 3.66C per KW11 June - September First 150 KW11 per month 8.220 per KW11 Next 350 KWII per month 6.31c per KWH Next 1500 KMI per month 4.990 per KWH Next 2000 KW11 per month 4.460 per KW11 Excess K1411 per month 3.9'3c� per KWH MINIMUM MONTHLY CHARGE: Single phase - - -- $2.00 per month Three phase - - -- $2.00 per month plus First connected horsepower - -- $1.00 Additional horsepower -- - - - - -- $ .50 This rate subject to Power Cost Adjustment,. HUTCHINSON UTILITIES COMMTSSION _ ELG -7 - 79 i ELECTRIC LARGE GENERAL SERVICE APPLICABILITY: Applicable to any customer for combined power and lighting with a minimum demand of 50 kilowatts for single or three phase electric service supplied through one meter at the secondary voltage at that location. October.- May Demand Charge: $3.00 per kilowatt of demand per month Energy Charge: First 2,000 KWR per month 4.671 - - -- per KWH Next 2,000 K11I1 per month 3.61 - - -- per KWH Excess KWR per month 3.08 - - -- per KWI June - September Demand Charge: $4.00 per kilowatt of demand per month Energy Charge: First 2,000 KWH per month 4.67C - - -- per KWIC Next 2,000 KWH per month 3.610 - - -- per KWH Excess KWii per month 3.08 - - -- per KWH MINIMUM MONTHLY CHARGE: 75% of the maximum demand charge for the previous October - May billings or 50% of the maximum June -- September demand charge, whichever is greater. SERVICE AT PRIMARY VOLTAGE If service is taken at the primary voltage available at the customer's location and the customer assumes all cost of ownership, maintenance and replacement of connection facilities except metering, a discount of 5% will be allowed. This adjustment includes the discount for primary metering. METERING AT PRIMARY VOLTAGE: If, at the discretion of the utility, service is metered at primary voltage, a 2% discount will be allowed on energy charge. This rate subject to Power Cost Adjustment. The above rates are based on an assumed average monthly power factor of 90% lagging. The Commission reserves the right to monitor or install metering equipment to determine the power factor. If the power factor is below 90% lagging, then the demand for billing purposes shall be the metered demand - multiplied by 90 %, and the product therefore divided by the monitored power factor in percent. No adjustment shall be made if the power factor is above 90% lagging. ozl�2- SECURITY LICIT(' RENIAI, ESL -7 -79 RATE TO FURNISH AND MAINTAIN FIXTURE: MERCURY VAPOR: tights will be dusk to dawn type with photo control and will be installed ;ix existing pole in the area. If a new pole is needed, customer will pay fdr the pole and installation. STREET LIGHTLVG CHARGE: 3.5C per Kkgj This rate subject to Power Cost Adjustrr nt. Monthly Monthly Lamp Size Charge Lamp Size Cha- rEe 175 watt metered $2.50 175 watt unmetered $5.50 400 watt metered $3.00 400 watt unmetered $9.30 HIGH PRESSURE SODIUM: Monthly Monthly Lamp Size Char 1,.unp Sizc' Charge 150 watt metered $2.50 150 watt unmetered $5.50 250 watt metered $3.00 250 watt. unmetered $7.50 tights will be dusk to dawn type with photo control and will be installed ;ix existing pole in the area. If a new pole is needed, customer will pay fdr the pole and installation. STREET LIGHTLVG CHARGE: 3.5C per Kkgj This rate subject to Power Cost Adjustrr nt. t (3,<q FARM RATE FR- 7- 79 All rural customers (other than three- phase and all electric homes) who have a tract of land devoted to the production of crops, livestock, or poultry and whose dwelling and other farm buildings are on one meter, will receive the first 1600 KWII at Residential Rate. The excess of 1600 KWII will be charged at the Small Electric General Service Rate beginning with step one. October - May June - September 300 KWII @ .0600 1300 KWII @ .0400 150 IMI. @ .0822 150 KWII @ .0822 350 KWH @ .0631 350 KWII @ .0631 1500 I%'ll @ .0472 1500 KI-11I @ .0499 2000 KWII @ .0419 2000 KWII @ .0446 Excess KWII @ .0366 Excess KWH @ .0393 These rates subject to Power Cost Adjustmcrnt. ilUTC 1INSON UTILITIES COTIl Sti 10'4 ELI -7 -79 ELECTRIC LARGE INDUSTRIAL SERVICE. APPLICABILITY: Applicable to any industrial customer for combined power and lighting with a minimum demand over 4000 KW during any one month in 12 month period. Service will be delivered at the primary voltage available at the clr?tomer's property line. The customer will own and maintain all electrical facilities on the customer's side of the metering transformers. DEMAND CHARGE: Minimum $16,960 Includes first 4,000 KVA of billing KVA demand. Excess demand over 4,000 KVA, $2.12 per billing KVA demand. ENERGY CHARGE: All energy at 2.60c per KV 11 BILLING KVA DEMAND: Billing KVA demand will be greater of the following: Maximum actual K14 monthly demand divided by the average monthly lagging power factor or 75% of the maximum actual KW monthly demand during the previous 11 months divided by the average monthly lagging power factor of the billing month. This rate subject to Power Cost Adjustment. POWER COST ADJUSTk1lINT (Electric) Power Cost Adjustment is based on the combined co is of fuel, lubricants, maintenance of generating untts* used in the = Hutchinson electrical generating stations and purchased power from outside suppliers. Each monthly electrical bill shall be increased by $.00011 per MI for each $.00010 that the combined cost of fuel, lubricants, maintenance and purchased power exceed, $.0215 per M[. Computations of power adjustment shall he made monthly. The resultant adjustment, if any, shall be appltcahlc- for the month. Maintenance is defined as the average monthly cost for the previous half year that exceeds $14,000 per month. These rate changes to be submitted to the Honorable Mayor and City Council for acceptance at the earliest date. Upon acceptance, rates would be effective with the August 1, 1979 billing. After discussion, it was decided to send letters to those customers being changed from Electric Small General Service to Electric Large General Service, also allowing those customers affected by 25 HP motors or greater three months to install capacitors. The meeting was adjourned at 1:55 p.m. Ruttz`�akel, Assistant Secretary ATTEST— T H. P. Quade, President 1